Equipment Laboratory


Organic Analysis

HPLC 1100, High-Performance-Liquid-Chromatograph, (Agilent Technologies), degasser, binary pump, column oven, variable wavelength detector (UV), fluorescence detector, Chemstation-software

ASE 200 Accelerated Solvent Extractor, (Dionex), sequential extraction of max. 24 samples, 12 cells á 1 ml, 5 ml, 11 ml und 33 ml each, ASE-solvent module, Auto-ASE-Software

 

LABORATA 4003 control vario HB G3B, Rotary Evaporator, Heidolph, RPM-regulated vacuum pump, programmable

LECO-TOC RC612, multiphase carbon/water analyser

VarioMacro (Elementar), Elemental Analyzer for CHNS incl. a Mettler MX5 microbalance kit. Sample combustion at temperatures up to 1150 °C and detection by WLD

 

 

SFE AutoPrep 44 System, Supercritical Fluid Extraction, Suprex, carbondioxide (liquid), Accu Trap, Modifier Pump, 2 Vari Pumps (dual-piston pump system)   

Syncore Analyst R-12* (Büchi), simultaneous vacuum evaporation of up to 12 samples (120 ml), residual volume 1 ml, water cooling, vacuum pump V-700 Professional with  Controller V-855, Condenser, Flushback-Module

 


Vapotherm Basismobil I* (Barkey),  simultaneous evaporation of up to 10 samples (10 ml), adjustable temperature and nitrogen stream

Autotrace SPE-Workstation (Zymark), Solid-Phase Extraction, sequential and independent extraction of 6 water samples

 


GC-MS 1 (Agilent Technologies), Gas Chromatograph (GC) 6890N coupled to a mass spectrometer (MS) 5975 inert Mass Selective Detector (MSD) with a quadrupole mass analyzer and a CTC Combi PAL as the sampling device

 


ITEX-2 Option PAL (CTC Analytics): The solventless in-tube microextraction (ITEX-2) performs enrichment of volatile or semi-volatile compounds during headspace analysis.

 


GC-MS 2 (Agilent Technologies), GC 7890A coupled to a 5975C inert XL MSD with a quadrupole mass analyzer and a 7683B Series autosampler.       
    

GC-HS (Agilent Technologies), Agilent 7890, Perkin Elmer HS40, headspace analysis of gases and volatile compounds

 




Inorganic Analysis

icpTOF, a combination of the iCAP Q (Thermo Scientific) and the TOFMS (TOFWERK AG) allowing for quasi-simultaneous detection of the elemental mass range (m/z 7-250) with extremely rapid acquisition rates (46μsec).

ICP-MS "8800" with Triple Quad (ICP-QQQ), high sensitivity and low background

ICP-MS 7900 provides short integration times for accurate analysis of transient signals. New orthogonal detector system delivers up to 11 orders of magnitude dynamic range.

ICP-OES "Optima 5300DV" with Mercury Flow Injection System ("FIMS 100"), MiraMist Nebulizer

ICS-1000, Ion Chromatography by Dionex, dual-piston pumping, electrolytic suppression, vacuum degas, Chromeleon SE 6.6 software)   

SeaFast Sample Introduction System, Automated, column-based, FIA matrix removal and analyte pre-concentration system. Enhances detection limits and matrix tolerance for REE before ICP-MS analysis

ESI-Apex-Q, desolvation nebulizer produces a dry aerosol from liquid samples for analysis with ICP-MS for the reduction of polyatomic interferences and signal enhancement for selected analytes.

Microwave 3000-Anton Paar 1400 W microwave power ensures fast heating, unpulsed microwave for precise control of critical reactions, fast and homogeneous heating, reduced spontaneous reactions or charring, reliable remote sensors for convenient operation, protection against overheating with high boiling reagents, interference-free temperature probe design   

Speedwave 4-Berghof , designed for pressure digestion at temperatures up to 230° C (446° F) in continuous use and, depending on the type of vessels employed, pressures up to a max. of 100 bar (1450 psi).

Wyatt Dawn Heleos2, light scattering photometer. The ultimate flow-through static and dynamic light scattering photometer. For the determination of molecular weight and particle size in flow-through and batch mode. Operational range 10 - 700 nm (static LS) and 5 to 300 nm (dynamic LS), typically used in connection to FFF and SEC systems.


Perkin Elmer PinAACle 900T, Atomic Absorption Spectrometer versatile Flame- and Graphite Furnace-AAS system. For determination of metals in the ppm (flame) to ppb (GF) concentration range.



Isotope Analysis

Picarro L1115-i Isotopic Liquid Water and Water Vapor Analyzer    

DURRIDGE RAD7 & RAD H2O portable electronic radon detector with real time monitoring and spectral analysis, and an accessory that enables to measure radon in water.   


Colloid Analysis

Wyatt Eclipse 3+: Asymmetric Flow-Field Flow Fractionation.
Continuous fractionation of polymers and nanoparticles from 1 nm to 1 µm based on hydrodynamic principles. Detection of particles with Agilent 1200 UV-DAD detector, Agilent 1200 3D-fluorescence detector, on-line static and dynamic light scattering (Wyatt DAWN HELEOS II) and ICP-MS (Agilent 7700x). Provides a physical separation of particles, determination of particle size distributions, main and trace element size distributions, particle shape distributions, molecular conformation of polymers and branching ratios.


Wyatt Eclipse 3+: Asymmetric Flow-Field Flow Fractionation.
Continuous fractionation of polymers and nanoparticles from 1 nm to 1 µm based on hydrodynamic principles. Detection of particles with Agilent 1200 UV-DAD detector, Agilent 1200 3D-fluorescence detector, on-line static and dynamic light scattering (Wyatt DAWN HELEOS II) and ICP-MS (Agilent 7900). Provides a physical separation of particles, determination of particle size distributions, main and trace element size distributions, particle shape distributions, molecular conformation of polymers and branching ratios.


Metrohm Autotitrator, robotic autotitration system with autosampler, 6 dosing units, 2 robotic stands and various options for liquid handling and analysis operated by PC and tiamo software.
  

PostNova F2000 Focus: Asymmetric Flow-Field Flow Fractionation. Continuous fractionation of polymers and nanoparticles from 1 nm to 1 µm based on hydrodynamic principles. Detection of particles with UV-DAD detector, 3D-fluorescence detector, differential refractive index detector, on-line static and dynamic light scattering (Wyatt Dawn EOS) and ICP-MS (Perkin Elmer Elan 6100).
Provides a physical separation of particles, determination of particle size distributions, main and trace element size distributions, particle shape distributions, molecular conformation of polymers and branching ratios. This system is in particular best suited for polymers and small particles (1 - 100 nm) and for samples with low concentrations of nanoparticles (< 1 mg/L).  
 

Postnova Sedimentation / Centrifugal - Field Flow Fractionation (CFFF or SedFFF). Continuous fractionation of nanoparticles from 10 nm – 1 µm and density > 1g/cm³ according to their buoyant mass (diameter and density difference to carrier medium). Detection of particles with Agilent 1200 and 1260 UV-DAD and fluorescent detectors, online static and dynamic light scattering (Wyatt DAWN EOS or Heleos2) and ICP-MS (Agilent 7900 or 8800).

Eyetech (Ambivalue): particle analysis combining a laser and a video channel. Particle size distributions are measured based on laser obscuration time measurement principle. Shape analyses, concentration and surface area can also be derived. Operating range: 0.6-3600 µm. Magnetic, mechanical and flow through cells.    

PostNova F1000: Symmetric Flow-Field Flow Fractionation. Original design of Prof. Calvin Giddings and FFFractionation Utah (US) with improvements. Continuous fractionation of particles from 1 nm to 1 µm based on hydrodynamic principles. Detection of particles with UV-DAD detector, 3D-fluorescence detector, differential refractive index detector, on-line static and dynamic light scattering (Wyatt Dawn EOS) and ICP-MS (Perkin Elmer Elan 6100). Provides a physical separation of particles, determination of particle size distributions, main and trace element size distributions, particle shape distributions, molecular conformation of polymers and branching ratios. This system features two HPLC pumps to maintain symmetric cross-flow conditions without re-circulating the cross-flow. This prevents the contamination of the sample in the channel by re-introducing sample components smaller than the accumulation membrane size cut-off through the upper frit. This system is in particular best suited for medium to large nanoparticles (10 - 1000 nm) and for samples with higher concentrations of nanoparticles (> 10 mg/L).    

Quantachrome Nova 2000 e-series: specific surface area, pore volume and pore size distribution measurements based on N2 and CO2 physisorption.  

Malvern ZetaSizer Nano: Determination of molecular weight, hydrodynamic radius and zeta-potential. Based on dynamic light scattering at large angle (back-scattering, hydrodynamic radius) or 90° (molecular weight) and laser-doppler anemometry (zeta-potential). Additionally equipped with a multi-purpose titrator for the determination of zeta-potential and particle size (simultaneously) as a function of pH or ionic strength. Working range 3 nm - 3 µm (1 µm with mineral particles, 0.7 µm with iron-oxides), detection limits depending on particle size but typically < 1 mg/L.   

Galai CIS-1: determination of particle-number based particle size distributions based on laser-light shading/obscuration. Significantly lower detection limits than MS2000 (~ 1 mg /L), working range 0.5 µm - 300 µm.   

Malvern MasterSizer 2000 with HydroS (180 mL) and micro-Precision (18 mL) dispersing units: particle sizing based on light scattering and diffraction. Working range: 0.02 µm to 2000 µm (theoretical); 100 nm - 1 mm (practical) at concentrations down to ~ 100 mg/L. Enables the determination of particle-volume based size distributions, aggregation behaviour and aggregation kinetics as well as the characterization of aggregate formation (RLA or DLA) and the aggregates fractal dimensions.   

Wyatt Technology DawnEOS laser light scattering photometer. Used in conjuction with Field Flow Fractionation or size exclusion chromatography for the on-line determination of molecular and particle properties as molecular weight, RMS radius and hydrodynamic radius. Batch operation possible with batch conversion kit. 30 mW laser source at 690 nm, observation of scattered light at 18 angles (static light scattering) and dynamic light scattering observed at 100° angle (APD detector and ALV 5000 auto-correlator-board).   

Turbiscan LABExpert (Formulaction): Determination of the dispersion state of dispersions, emulsions etc..Transmission and backscattering detector. Particle migration can be followed by scanning the total height of the sample. The Expert version includes thermoregulation and models to compute physical parameters such as the dispersion state or the particle diameter.    

Fluoromax-4 (HORIBA Scientific): Spectrofluorometer equipped with auto-titrator unit F3006 and Fiber-Optics adapter FM4-3000.    

SurPASS (Anton Paar): Electrokinetic Analyzer for solid samples. Zeta potential determination is based on the measurement of streaming potential and streaming current. Equipped with the Cylindrical Cell used for e.g., granular samples, coarse particles, or fibres (particle size >25 µm), and the Adjustable Gap Cell used for small samples with a rectangular shape e.g., membranes (20x10 mm, thickness <2 mm).    


Other Equipment

Atlas SUNTEST CPS+, Weathering instrument equipped with air-cooled Xenon Lamp.

Horiba XGT-7000 X-Ray Fluorescence spectrometer / microscope, Elemental analysis of surfaces with X-Ray fluorescence. By Single Point analysis, Multi-point Analysis, or Mapping Analysis. X-ray guide tubes with diameters ranging from 10 µm to 100µm. It is possible to switch between a high sensitivity full vacuum mode and a versatile localised vacuum mode. Sensitivity to all elements from sodium to uranium. are possible. X-ray tube: Rh target /Tube voltage 50kV, Fluorescent X-ray detector: High pure Si detector   
 

Beckman Coulter Optima L-100 XP Ultracentrifuge Max speed 55000 rpm (360000 G) with swinging bucket rotor   

Alpha 1-4 LSC, freezing dry machine, Christ, 0,37 kW, ice condenser temperature -55 °C, ice condenser chamber 6,5 l, 5 shelves á 360 mm diameter, modul HED-16 LSC (adaptable for heated shelves), LYOLOG LL-1 software   
 

Water Purification System: Elix 5 and MilliQ Gradient A10, (Merck Millipore) automatic disinfection module, typical electrical conductivity 0,056 µS/cm, typical silicate concentration below 20 ppb, typical TOC-concentration below 5 ppb, elimination of particles / colloids > 99% 

 

 

Millipore Advantage with RIOS3 and Q-Pod Dispenser, typical electrical conductivity 0,056 µS/cm, typical silicate concentration below 20 ppb, typical TOC-concentration below 4 ppb   

Zentrifuge CR 422 

Zentrifuge Cyrofuge 6000i